BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//ChamberMaster//Event Calendar 2.0//EN
METHOD:PUBLISH
X-PUBLISHED-TTL:P3D
REFRESH-INTERVAL:P3D
CALSCALE:GREGORIAN
BEGIN:VEVENT
DTSTART:20260630T130000Z
DTEND:20260630T220000Z
X-MICROSOFT-CDO-ALLDAYEVENT:FALSE
SUMMARY:Vapor Distribution Refresher- Bemidji
DESCRIPTION:Vapor Distribution 4.1 and 4.2 Refresher \n\nThis class combines the best of the essential parts of Vapor Distribution 4.1 and 4.2.  This class will review all the appropriate inspections\, tests and procedures necessary to put a vapor propane system back into operation after an interruption of service\, alteration of the system\, out of gas situation or after a 'leak' or 'I smell gas' type of service call. In addition\, the class will review the tasks and procedures required in selecting\, delivering and installing propane containers\, piping systems and regulators for customers. The class will cover the following:\n\n \n\nThis training will include an end of session test and certificates of completion.\n\n  A brief review of the exterior propane system & 2 stage systems\; 2# systems\n\n  Conducting interior site assessment of piping and appliance\n\n  Review and inspection of venting and ventilation\n\n  Procedures for leak checking a system\n\n  Purging air from gas piping systems & Placing appliances into operation\n\n  Selecting\, loading and transporting legal containers\n\n  Underground tank installation and cathodic protection\n\n  Installing containers and lines\,\n\n  Proper line sizing and line material selection\n\n  Selecting and installing regulators and meters\n\n  Conducting performance tests for installed regulators (flow and lock-up)
X-ALT-DESC;FMTTYPE=text/html:<span style="text-decoration:underline\;text-underline:single\;font-weight:bold\;language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">Vapor Distribution 4.1 and 4.2 Refresher </span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">This class combines the best of the essential parts of Vapor Distribution 4.1 and 4.2.&nbsp\; This class will review all the appropriate inspections\, tests and procedures necessary to put a vapor propane system back into operation after an interruption of service\, alteration of the system\, out of gas situation or after a &lsquo\;leak&rsquo\; or &lsquo\;I smell gas&rsquo\; type of service call. In addition\, the class will review the tasks and procedures required in selecting\, delivering and installing propane containers\, piping systems and regulators for customers. The class will cover the following:</span></span></span><br />\n&nbsp\;<br />\n<span style="text-decoration:underline\;text-underline:single\;language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">This training will include an end of session test and certificates of completion.</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; A brief review of the exterior propane system &amp\; 2 stage systems\; 2# systems</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Conducting interior site assessment of piping and appliance</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Review and inspection of venting and ventilation</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Procedures for leak checking a system</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Purging air from gas piping systems &amp\; Placing appliances into operation</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Selecting\, loading and transporting legal containers</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Underground tank installation and cathodic protection</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Installing containers and lines\,</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Proper line sizing and line material selection</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Selecting and installing regulators and meters</span></span></span><br />\n<span style="language:en-US\;"><span style="font-family:calibri\;"><span style="font-size:12.0pt\;">&bull\; Conducting performance tests for installed regulators (flow and lock-up)</span></span></span><br />\n&nbsp\;
LOCATION:Country Inns & Suites 927 Lake Shore Dr NE Bemidji MN 56601 218-558-5174
UID:e.9523.748
SEQUENCE:3
DTSTAMP:20260405T042858Z
URL:http://mnpropane.memberzone.com/events/details/vapor-distribution-refresher-bemidji-748
END:VEVENT

END:VCALENDAR
