BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//ChamberMaster//Event Calendar 2.0//EN
METHOD:PUBLISH
X-PUBLISHED-TTL:P3D
REFRESH-INTERVAL:P3D
CALSCALE:GREGORIAN
BEGIN:VEVENT
DTSTART:20260721T130000Z
DTEND:20260721T220000Z
X-MICROSOFT-CDO-ALLDAYEVENT:FALSE
SUMMARY:Service Tech - Inside - Zimmerman
DESCRIPTION:NOTE: This course replaces CETP 4.2/4.3 Vapor Distribution Systems: Placing Systems into Service and Interior Vapor Distribution Systems.\n\nPrerequisite required: Service Tech   Outside or CETP 4.1 Vapor Distribution Systems: Exterior Piping.\n\nThis course focuses primarily on the procedure of placing a vapor distribution system into operation on the interior of the house or downstream of the second stage regulator. We will be focusing on NFPA 54 requirements. Bring your NFAP 54 book to class. \n\nThe topics covered are:\n\n	Installing interior piping\n	System tests\n	Validating the container\n	Regulator placement and operation \n	Making the final connections to the propane system \n	Purging air out of the gas lines\n	Appliance controls and safety\n	New appliances start up\n	How to adjust burners on appliances
X-ALT-DESC;FMTTYPE=text/html:<strong><span style="font-size:12.0pt\;">NOTE: </span></strong><span style="font-size:12.0pt\;">This course replaces CETP 4.2/4.3 Vapor Distribution Systems: Placing Systems into Service and Interior Vapor Distribution Systems.</span><br />\n<strong><span style="font-size:12.0pt\;">Prerequisite required: </span></strong><span style="font-size:12.0pt\;">Service Tech &ndash\; Outside or CETP 4.1 Vapor Distribution Systems: Exterior Piping.</span><br />\n<span style="font-size:12.0pt\;">This course focuses primarily on the procedure of placing a vapor distribution system into operation on the interior of the house or downstream of the second stage regulator. We will be focusing on NFPA 54 requirements. Bring your NFAP 54 book to class.&nbsp\;</span><br />\n<span style="font-size:12.0pt\;">The topics covered are:</span>\n<ul>\n	<li><span style="font-size:12.0pt\;">Installing interior piping</span></li>\n	<li><span style="font-size:12.0pt\;">System tests</span></li>\n	<li><span style="font-size:12.0pt\;">Validating the container</span></li>\n	<li><span style="font-size:12.0pt\;">Regulator placement and operation </span></li>\n	<li><span style="font-size:12.0pt\;">Making the final connections to the propane system </span></li>\n	<li><span style="font-size:12.0pt\;">Purging air out of the gas lines</span></li>\n	<li><span style="font-size:12.0pt\;">Appliance controls and safety</span></li>\n	<li><span style="font-size:12.0pt\;">New appliances start up</span></li>\n	<li><span style="font-size:12.0pt\;">How to adjust burners on appliances</span></li>\n</ul>\n
LOCATION:Minnesota Propane Association 12475 273rd Ave NW Zimmerman MN 55398 763-633-4271
UID:e.9523.724
SEQUENCE:3
DTSTAMP:20260405T044142Z
URL:http://mnpropane.memberzone.com/events/details/service-tech-inside-zimmerman-724
END:VEVENT

END:VCALENDAR
